Ion Exchange (IEX) Columns

Ion exchange chromatography (IEX) is widely used for analysis and purification of biomolecules. These columns are used for the separation of proteins, peptides, and nucleic acids. BioPro IEX columns are based on porous and non-porous hydrophilic polymer beads with low nonspecific adsorption. These columns are available in QA and SP chemistries and are based on porous (QA and SP columns) and non-porous (QF and SF columns) hydrophilic polymer beads with low nonspecific adsorption.

They also show higher binding capacity and higher recovery of biomolecules compared to conventional IEX columns.

Monoclonal antibody (MAb) analysis on non-porous type cation exchange columns

Excellent batch-to-batch reproducibility

30 mm-length column for high-throughput analysis with low operating pressure

High binding capacity and high recovery of biomolecules

High loadability

 
(formerly)
BioPro IEX QA
(YMC-BioPro QA)
BioPro IEX SP
(YMC-BioPro SP)
BioPro IEX QF
(YMC-BioPro QA-F)
BioPro IEX SF
(YMC-BioPro SP-F)
Matrix Hydrophilic polymer (polymethacrylate)
Particle Size 5 µm 3, 5 µm
Pore Size 100 nm / 1000 Å Non-porous
Charged group -CH2N+(CH3)3 -(CH2)3SO3- -CH2N+(CH3)3 -(CH2)3SO3-
Counter ion Cl- Na+ Cl- Na+
Ion-exchange capacity 0.075-0.100 meq/ml-resin 0.070-0.095 meq/ml-resin 0.075-0.110 meq/ml-resin 0.230-0.290 meq/ml-resin
Dynamic binding capacity 110-150 mg BSA/ml-resin 70-100 mg human IgG/ml-resin 12-20 mg BSA/ml-resin 10-18 mg human IgG/ml-resin
pH range 2.0 - 12.0
 
(formerly)
BioPro IEX QA
(YMC-BioPro QA)
BioPro IEX SP
(YMC-BioPro SP)
Matrix Hydrophilic polymer (polymethacrylate)
Particle Size 5 µm
Pore Size 100 nm / 1000 Å
Charged group -CH2N+(CH3)3 -(CH2)3SO3-
Counter ion Cl- Na+
Ion-exchange capacity 0.075-0.100 meq/ml-resin 0.070-0.095 meq/ml-resin
Dynamic binding capacity 110-150 mg BSA/ml-resin 70-100 mg human IgG/ml-resin
pH range 2.0 - 12.0
<
 
(formerly)
BioPro IEX QF
(YMC-BioPro QA-F)
BioPro IEX SF
(YMC-BioPro SP-F)
Matrix Hydrophilic polymer (polymethacrylate)
Particle Size 3, 5 µm
Pore Size Non-porous
Charged group -CH2N+(CH3)3 -(CH2)3SO3-
Counter ion Cl- Na+
Ion-exchange capacity 0.075-0.110 meq/ml-resin 0.230-0.290 meq/ml-resin
Dynamic binding capacity 12-20 mg BSA/ml-resin 10-18 mg human IgG/ml-resin
pH range 2.0 - 12.0
Title Document Type Language Phase Type Download
HPLC Analysis of Oligonucleotides with BioPro IEX QF Application Note E Download
Optimisation of oligonucleotide separations using YMC´s non porous anion exchanger BioPro IEX QF Application Note E Download
YMC Biochromatography Columns Brochure E Download
YMC Biochromatography Columns (HQ) Brochure E Download
BioPro IEX Columns Care and Use Care and Use Instructions E Download
Analytical stationary phases for BioLC from YMC Overview E Download
The Principles of BioLC & YMC BioLC Phase Overview Poster E Download
Characterisation of charge heterogeneity of therapeutic monoclonal antibodies via IEX-MS using BioPro IEX SF from YMC Product Information E Download